National Repository of Grey Literature 10 records found  Search took 0.01 seconds. 
Motion Analysis
Hudec, Jiří ; Čmiel, Vratislav (referee) ; Sekora, Jiří (advisor)
Bachelor thesis is dealing with how to analyze human walk with Vicon camera system. In the first chapter are described elementary ideas for gait analysis and principal methods of Vicon system. There is also discussed basic layout of cameras in the laboratory and layout of markers attached at a human body. The second chapter is also about synchronisation of multiple cameras and description of CVS format. Further, in the third chapter are discussed four algorithms created in Matlab for a description of gait analysis. In the last fourth chapter are discussed the results of the software from Matlab and comparison these results with results made in the laboratory of gait analysis.
Kinetic analysis of signals from gait laboratory.
Benešovská, Veronika ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
Gait analysis has an irreplaceable meaning in many various fields. Thanks to the Vicon system, which is used in gait laboratory, the movement of individual body parts can be captured. The purpose of this work is to process data records from gait laboratory, and kinetic analysis in Matlab program. The main target of the bachelor thesis is to compare detected values, which were evaluated by kinetic analysis of the data obtained from tested subject during performing the exercise and creating GUI.
Advanced analysis of signals from gait laboratory.
Húsková, Michaela ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
The aim of the thesis is a realization of advanced analysis of signals from gait laboratory. The introductory part deals with the gait cycle and its relation to the joints kinematic is discussed. Additionally, the work is focused on the description of the gait laboratory and the definition of the indexes in order to quantify patient´s overall gait in kinematic analysis. In the practical part, kinematic data analysis was implemented in the MATLAB environment and the results of healthy individuals and patients with cerebral palsy were compared. Kinematic analysis included peak detection in specific kinematic variables. In the last part a graphical user interface for visualization was implemented.
Motion Analysis
Hudec, Jiří ; Čmiel, Vratislav (referee) ; Sekora, Jiří (advisor)
The thesis describes the optical camera system from Vicon, which records human movement. In medicine, this technology is used in laboratories for walk analysis. In collaboration with the laboratory in the Brno Faculty Hospital, two sets of anonymised patient results are analyzed by designed algorithms in Matlab. Algorithms were design for processing data in 2D and 3D views and to display kinematic joint analysis. The practical part evaluates the functionality of the proposed algorithms and compares them with results from the laboratory.
Kinetic and kinematic gait analysis using VICON system
Hrdličková, Alžběta ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
The Vicon optoelectronic system can be used to analyze human walking. This measurement greatly helps to diagnose problems with the motion apparatus. This work deals with the use of this system for the measurement of kinematic and kinetic values of joints for lower body model. The main aim of the bachelor thesis is to compare the results of healthy patients and patients with cerebral palsy. The theoretical part deals with the description of the gait cycle from kinematics and kinetics, and also description of the device for the analysis. In the practical part, automatic detection of values is proposed, which were evaluated, compared and discussed in the last part.
Advanced analysis of signals from gait laboratory.
Húsková, Michaela ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
The aim of the thesis is a realization of advanced analysis of signals from gait laboratory. The introductory part deals with the gait cycle and its relation to the joints kinematic is discussed. Additionally, the work is focused on the description of the gait laboratory and the definition of the indexes in order to quantify patient´s overall gait in kinematic analysis. In the practical part, kinematic data analysis was implemented in the MATLAB environment and the results of healthy individuals and patients with cerebral palsy were compared. Kinematic analysis included peak detection in specific kinematic variables. In the last part a graphical user interface for visualization was implemented.
Kinetic analysis of signals from gait laboratory.
Benešovská, Veronika ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
Gait analysis has an irreplaceable meaning in many various fields. Thanks to the Vicon system, which is used in gait laboratory, the movement of individual body parts can be captured. The purpose of this work is to process data records from gait laboratory, and kinetic analysis in Matlab program. The main target of the bachelor thesis is to compare detected values, which were evaluated by kinetic analysis of the data obtained from tested subject during performing the exercise and creating GUI.
Kinetic and kinematic gait analysis using VICON system
Hrdličková, Alžběta ; Mézl, Martin (referee) ; Svozilová, Veronika (advisor)
The Vicon optoelectronic system can be used to analyze human walking. This measurement greatly helps to diagnose problems with the motion apparatus. This work deals with the use of this system for the measurement of kinematic and kinetic values of joints for lower body model. The main aim of the bachelor thesis is to compare the results of healthy patients and patients with cerebral palsy. The theoretical part deals with the description of the gait cycle from kinematics and kinetics, and also description of the device for the analysis. In the practical part, automatic detection of values is proposed, which were evaluated, compared and discussed in the last part.
Motion Analysis
Hudec, Jiří ; Čmiel, Vratislav (referee) ; Sekora, Jiří (advisor)
Bachelor thesis is dealing with how to analyze human walk with Vicon camera system. In the first chapter are described elementary ideas for gait analysis and principal methods of Vicon system. There is also discussed basic layout of cameras in the laboratory and layout of markers attached at a human body. The second chapter is also about synchronisation of multiple cameras and description of CVS format. Further, in the third chapter are discussed four algorithms created in Matlab for a description of gait analysis. In the last fourth chapter are discussed the results of the software from Matlab and comparison these results with results made in the laboratory of gait analysis.
Motion Analysis
Hudec, Jiří ; Čmiel, Vratislav (referee) ; Sekora, Jiří (advisor)
The thesis describes the optical camera system from Vicon, which records human movement. In medicine, this technology is used in laboratories for walk analysis. In collaboration with the laboratory in the Brno Faculty Hospital, two sets of anonymised patient results are analyzed by designed algorithms in Matlab. Algorithms were design for processing data in 2D and 3D views and to display kinematic joint analysis. The practical part evaluates the functionality of the proposed algorithms and compares them with results from the laboratory.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.